Skip to content
English
  • There are no suggestions because the search field is empty.

Pump Out from ETI

1694111683984

Introduction


This article is designed to provide you with a comprehensive understanding of the process involved in performing a pump-out at customer locations using your ETI meter, or alternatively, through manual entry.

A "pump-out" typically refers to the removal of liquid contents, often from a storage tank or container. In the context of commercial vehicles, particularly those transporting liquids like fuels or chemicals, a pump-out is a crucial operation. It involves transferring the contents of the vehicle's storage tanks, such as those carrying fuels or other fluids, to another container or system at a customer's location. This process can be performed using specialized equipment like a pump-out system or meter, which accurately measures the quantity of liquid being transferred.

This article will guide you through the steps and procedures necessary for executing a successful pump-out operation using your ETI meter, which is designed to facilitate precise measurements and data collection. Alternatively, it will also explain how to manually record and manage pump-out activities, ensuring that you have a comprehensive understanding of both methods to meet your operational needs effectively.

Setup


This portion of the article will guide you through the items you need to setup, before preforming a pump out in Mango Mobile.

Propane Product Charge Code

  1. Must have a product class code that has "Direct Meter Transfer" enabled.

1694111863563

2. Assign your Propane product as a default product to your customers under Lists > Customer Information > Default Products.

1694111818746

3. HH Class > Sales Rules 2 > Direct Meter Transfer type set to LCR 2 (Direct Communication).

1694111724520

4. Connect your Meter to Mango Mobile

Process


Once you have downloaded a route in Mango Mobile, navigate to the customer you would like to service you can begin the pump out process.

Auto Pump Out

  1. From the Quick entry screen make sure the product displayed is your propane product charge code, then select the QTY field highlighted below to begin your pump-out

1694110075629

2. Select “Pump Out”.

1694110075674

3. Select "Connect to Meter".

1694110075717

4. Once the LCR is connected, Select Start to begin pumping out.

1694111046669

5. Select Stop and save the quantity once finished.

1694110075806

6. On the meter capture screen the the quantity will be negative as well.

1694110075891

7. The quantity will be displayed in a negative quantity on the quick sale screen, shopping cart, and invoice.

1694110075849

 

Manual Pump Out


  1. To manually enter a pump out, enter your quantity and select "Pump out". Selecting "Pump Out" will change the quantity to a negative. When you are finished, select the next arrows to complete your service.

1694110076002

 

Support


If you need further assistance from our support team please email us at support@advantagers.com or call us at 209-632-1122.